Description
Images are original technical illustrations, not EB product photographs or customer projects. They do not prove a manufacturing or test capability.
EB Castworld supplies custom CW2M nickel-alloy castings to purchaser-approved drawings for corrosive-fluid equipment. Enquiry geometries may include closed or open pump impellers, mixer rotors, agitator hubs, wear rings, diffuser components and selected valve internals. Each part is reviewed against the fluid envelope, casting route, heat treatment, machining, balance, weld-repair and inspection requirements. This page is not an alloy-selection guarantee and does not offer standard inventory or online purchase.
CW2M (UNS N26455) is a low-carbon Ni-Cr-Mo casting grade in ASTM A494. Its chemistry can be attractive for selected severe corrosion duties, but no alloy is universally resistant to every concentration, temperature, oxidizer, halide, deposit or crevice. The purchaser’s corrosion specialist must select the grade and approve the hydraulic/mechanical design.
Product and Component Range
| Component type | Drawing inputs | Important boundary |
|---|---|---|
| Closed pump impeller | Hydraulic passages, eye, vane thickness, hubs and balance plane | EB does not redesign pump performance without an agreed scope |
| Open/semi-open impeller | Vane profile, clearance surfaces and tip tolerances | Final clearance belongs to pump design |
| Mixer or agitator rotor | Blade geometry, shaft interface and service loads | Torque/fatigue rating remains purchaser responsibility |
| Wear ring or throat component | Fits, running clearance and anti-galling requirements | Mating material and start-up condition must be supplied |
| Valve/internal wetted casting | Flow path, sealing surfaces and pressure boundary | Design code and pressure rating are customer-controlled |
All products are manufactured to drawings. Final size, wall, surface finish, alloy, NDE, balance and acceptance depend on the approved RFQ.
Technical handover before quotation
A rotating wetted component requires three coordinated handovers. The corrosion specialist supplies the credible fluid envelope and confirms the selected alloy. The pump or mixer designer supplies the controlled hydraulic/mechanical geometry, loads, speed, fits and balance requirement. The procurement team converts both packages into a purchase specification with inspection, documentation and deviation rules. Omitting any handover leaves the casting supplier to guess decisions that belong to the equipment owner.
For an impeller, mark the vane inlet and outlet, hub transition, wear-ring interfaces, minimum wall, machining datums and permitted balance-correction areas. For a mixer component, include torque direction, cyclic duty, shaft attachment and any fatigue-sensitive transition. Identify which surfaces contact process fluid and which are later coated, ground or assembled. State whether a casting model is authoritative or whether the dimensioned drawing prevails when the two conflict.
The quotation should separate tooling, casting, heat treatment, rough machining, finish machining, NDE, PMI, dimensional scanning, balance and documentation. It should identify whether a first article or destructive qualification casting is required. If production quantity may change, provide both prototype and series quantities so the proposed casting route is realistic. No lead time should be accepted until tooling approval, material procurement and witness points are understood.
A deviation process is equally important. Proposed changes in alloy, welding, heat treatment, minimum wall, balance correction or inspection coverage require written purchaser disposition. Minor drawing clarifications should be recorded against the revision rather than handled through informal messages. At final release, the document index should connect the heat, casting serial, repair map, NDE reports, dimensions and balance results to the delivered part. This traceability is more useful than a generic certificate stating only that the component “passed inspection.”
ASTM A494 CW2M Material Basis
ASTM A494/A494M-26 is listed by ASTM as the active edition and covers nickel and nickel-alloy castings for corrosion-resistant service. It includes chemistry, heat treatment and tensile-property requirements. The ordered edition and applicable general requirements must be stated in the purchase order.
| ASTM A494 function | Supplier evidence | Purchaser addition |
|---|---|---|
| Grade identity | Certified heat analysis | Product analysis/PMI scope if required |
| Heat treatment | Traceable treatment route | Furnace records and any extra metallography |
| Mechanical compliance | Required tensile-test results | Additional impact/hardness tests if applicable |
| Casting requirements | General quality framework | Drawing zones, NDE extent and acceptance levels |
| Repair framework | Specification/contract provisions | Prohibited zones and approval threshold |
The specification does not define corrosion rate for the customer’s fluid, pump efficiency, cavitation margin, impeller trim or service life.
Ni-Cr-Mo Chemistry and CW2M Identity
The Nickel Institute publication on stainless steel and nickel-base castings lists CW2M as UNS N26455 with low carbon and a Ni-Cr-Mo alloy system. The active ASTM edition controls acceptance; the values below are technical orientation from that publication, not a substitute for purchased standards.
| Element | Technical-reference limit/range, wt.% | Engineering significance |
|---|---|---|
| C | 0.02 max | Low carbon supports corrosion/weld microstructure control |
| Cr | 15.0–17.5 | Contributes passivation in suitable environments |
| Mo | 15.0–17.5 | Supports resistance in many reducing/localized-corrosion conditions |
| Fe | 2.0 max | Controlled residual/balance within the grade |
| W | 1.0 max | Controlled addition/residual boundary |
| Ni | Remainder | Matrix basis; not a universal corrosion guarantee |
| Mn/Si/P/S | Controlled maxima | Melting, cleanliness and weld response considerations |
Require actual heat results. Do not write a nominal Internet table into an MTC or treat a supplier’s typical composition as the guaranteed ASTM range.
Corrosion-Service Data Needed for Quotation
CW2M selection is only meaningful against a defined environment. Provide normal, design, start-up, shutdown and cleaning exposures.
| Fluid parameter | Information required | Why it changes risk |
|---|---|---|
| Chemical species | Full composition and concentration range | Oxidizing/reducing behavior depends on mixture |
| Temperature | Bulk, metal, design and upset values | Corrosion kinetics and phase behavior change |
| Halides/oxidizers | Chloride, fluoride, ferric ions, hypochlorite, etc. | Localized or transpassive attack may control |
| pH and aeration | Range and dissolved oxygen/process state | Passive-film stability can change |
| Solids | Loading, size, hardness and shape | Erosion-corrosion and blockage can dominate |
| Velocity/cavitation | Pump duty, NPSH context and local turbulence | Removes films and damages impeller surfaces |
| Cleaning/shutdown | Acids, alkalis, steam, stagnant rinse and deposits | Off-normal condition can be most severe |
EB Castworld does not select CW2M based only on the fluid name. Provide corrosion-study or field-history references when available.

Casting Route and Hydraulic Geometry
Impellers and mixers have thin curved vanes, enclosed passages and heavy hubs. Casting route selection depends on envelope, weight, section transitions, quantity, surface requirement and NDE access. No single process is automatically best.
| Geometry issue | Foundry concern | RFQ response |
|---|---|---|
| Thin vane to heavy hub | Feeding and differential solidification | Provide minimum thickness and permitted radii |
| Closed passage | Core control and cleaning access | Define hydraulic profile and inspection method |
| Asymmetric rotor | Distortion and balance correction | State datums, balance grade and correction limits |
| Machined shaft bore | Subsurface exposure and fit | Give final fit, stock and post-machining PT |
| Repair-restricted wetted area | Corrosion and fatigue concern | Mark prohibited/approval zones on drawing |
Casting simulation may be proposed for risk review but does not guarantee an indication-free component. Inspection acceptance must remain explicit.
Heat Treatment and Microstructure Control
CW2M castings must receive the heat treatment required by the active material specification and approved manufacturing route. Time at temperature, load uniformity and cooling practice affect phase dissolution and corrosion behavior.
| Control | Required evidence | Limitation |
|---|---|---|
| Furnace/load identification | Traceable route card and chart | Setpoint alone does not prove part temperature |
| Solution-treatment cycle | Time-temperature record | Must follow grade and contract requirements |
| Cooling/quench | Medium, transfer and process record | Process record is not a corrosion guarantee |
| Hardness where specified | Method, load, location and values | Hardness cannot replace chemistry or metallography |
| Metallography where specified | Location, preparation, phase criteria | Destructive sample is location-specific |
If the component is repaired after final heat treatment, define whether repeat heat treatment is required or allowed. The purchaser approves deviations.
Weld Repair and Wetted-Surface Restrictions
The RFQ should state whether repair welding is permitted. For pump impellers, vane leading edges, high-stress hub transitions and sealing surfaces may require special restrictions. For pressure parts, applicable code rules also apply.
| Weld-repair control | RFQ decision | Supplier record |
|---|---|---|
| Approval threshold | Depth, area, location or code definition | Repair request and purchaser disposition |
| Filler metal | Compatible chemistry and corrosion intent | Certificate/lot traceability |
| WPS/PQR | Process, heat input and interpass variables | Qualified procedure |
| Post-weld treatment | Required/allowed route | Furnace chart or approved exception |
| Post-repair NDE | PT plus volumetric method where required | Report and repair map |
An undocumented blend or weld on a wetted surface is not acceptable evidence of conformance.
Machining, Fits and Surface Finish
Customers should supply final bore, keyway, taper, thread, seal face and wear-ring tolerances. Surface-finish requirements should distinguish hydraulic surfaces from fits and sealing areas. Overly broad finish callouts can add cost without improving function.
| Feature | Drawing requirement | Verification |
|---|---|---|
| Shaft bore/taper | Size, taper, runout and datum | Bore gauge/CMM/runout report |
| Keyway/spline | Standard, width, depth and orientation | Gauge/profile measurement |
| Seal/wear-ring face | Flatness, finish and runout | Surface and dimensional report |
| Vane profile | Profile tolerance and inspection points | Template, scan or CMM by agreement |
| Balance correction area | Permitted removal/addition and minimum wall | Balance report and final visual/PT |
Final correction must not violate minimum wall or enter a prohibited repair zone.
Dynamic and Static Balance Requirements
Balance is a system requirement. State whether static or dynamic balancing applies, the standard/grade, operating speed, key convention, mandrel/interface and residual-unbalance reporting. An impeller balanced on an undefined arbor may not reproduce assembly behavior.
| Balance input | Why required |
|---|---|
| Component mass and speed | Establishes balancing method/context |
| Balance standard and grade | Prevents ambiguous “balanced” statement |
| Datum and arbor fit | Controls setup repeatability |
| Key/keyless convention | Changes mass distribution |
| Correction limits | Protects vane, hub and corrosion allowance |
| Report format | Provides plane and residual values |
EB Castworld does not infer pump operating speed from component diameter.
NDE and Inspection Plan
| Method | Intended scope | Important variables |
|---|---|---|
| VT | Surface/workmanship | Cleaning, stage and acceptance criteria |
| PT | Surface-breaking indications on nonferromagnetic alloy | Coverage, dwell, sensitivity and stage |
| RT | Volumetric examination in accessible zones | Technique, image quality and severity level |
| UT | Qualified examination where geometry/material permits | Calibration and scan limitations |
| Dimensional | Drawing conformance | Datums, report points and instrument |
| PMI/OES | Sampled alloy identity | Locations, calibration and element limitations |
| Balance | Rotor mass distribution | Setup, grade and residual result |
“100% NDT” must be converted into named coverage and acceptance criteria. Nickel-alloy cast structure and curved passages can constrain UT/RT interpretation.

PMI, Product Analysis and Traceability
Portable XRF can screen Ni, Cr and Mo but does not reliably quantify carbon. Spark OES can include carbon with suitable calibration and surface preparation. Require a certified heat analysis first, then add PMI/product analysis if the risk justifies it.
The alloy PMI method guide explains how to define instrument checks and test locations. Every component should retain a heat/part traceability link through machining and packing.
Quality Document Package
| Document | Minimum content |
|---|---|
| Material certificate | ASTM edition, CW2M/N26455, heat chemistry and mechanical results |
| Heat-treatment record | Furnace/load, times, temperatures and cooling route |
| NDE reports | Procedure, personnel, zones, results and disposition |
| Weld dossier | Repair map, WPS/PQR, filler, treatment and post-repair NDE |
| Dimensional report | Drawing revision, datums and actual measurements |
| Balance report | Standard, grade, setup, planes and residual values |
| Traceability/packing | Part, heat, serial and PO-line mapping |
For the broader specification logic, review corrosion-resistant nickel alloy casting specification.
RFQ Checklist
- Controlled casting and finish drawings, model and revision.
- ASTM A494/A494M CW2M edition and any applicable equipment/design code.
- Quantity, target weight and delivery condition.
- Complete fluid, temperature, pressure, solids, velocity and cleaning data.
- Hydraulic profile, minimum wall, datums, fits and surface finishes.
- Casting route constraints and simulation/first-article expectations.
- Heat-treatment records and mechanical/metallurgical tests.
- Weld-repair permission, restricted zones and approval thresholds.
- VT/PT/RT/UT scope, stage, technique and acceptance criteria.
- PMI/product analysis, dimensional and balance requirements.
- MTC, third-party hold points, marking, preservation and packing.
Technical and Safety Boundary
CW2M chemistry alone cannot prove corrosion life, resistance to every acid or safe pump operation. The responsible corrosion specialist and equipment designer must approve the grade and service envelope. Cavitation, erosion, fatigue, crevice geometry and galvanic couples may control performance even when bulk corrosion data appears favorable.
Before removing or inspecting wetted components, isolate, drain, decontaminate and lock out the equipment under the plant procedure. EB Castworld does not provide operating or maintenance authorization through this page.
Send Drawings for Quote
Review factory capability, then send the drawing, fluid data and inspection plan or email sales@ebcastworld.com. EB Castworld will evaluate the feasible casting, heat-treatment, machining and inspection route before quotation. Final alloy, structure, dimensions, heat treatment, balance and acceptance follow the purchaser-approved drawing and PO.
Image sources and reuse permissions
- Featured image: Original schematic linking fluid, component and evidence requirements for CW2M castings. Original editorial technical schematic; illustration only, not an EB Castworld project or test record. Creator: EB Castworld editorial team. Original non-photographic technical schematic created for this product page; no AI image generator and no third-party project imagery used. EB Castworld source. Asset record.
- Figure 1: Original schematic describing the casting-to-verification route for CW2M rotating parts. Original editorial technical schematic; illustration only, not an EB Castworld project or test record. Creator: EB Castworld editorial team. Original non-photographic technical schematic created for this product page; no AI image generator and no third-party project imagery used. EB Castworld source. Asset record.
- Figure 2: Original schematic separating nominal chemistry, environmental review and purchaser approval. Original editorial technical schematic; illustration only, not an EB Castworld project or test record. Creator: EB Castworld editorial team. Original non-photographic technical schematic created for this product page; no AI image generator and no third-party project imagery used. EB Castworld source. Asset record.

