EB Castworld accepts drawing-based enquiries for AISI 4330V nickel-chromium-molybdenum-vanadium forged crankshafts and semi-finished heavy reciprocating-pump shaft forgings. Scope can include an open-die or other approved forged blank, preliminary heat treatment, rough machining, mechanical testing, ultrasonic examination and final machining when the complete drawing and acceptance plan are supplied. This is not a stocked crankshaft and does not claim API certification, a pressure rating, fatigue life, interchangeability or delivery time without contract review.
Send Drawings for Quote | RFQ Email: sales@ebcastworld.com | Factory Capability
The pump OEM or equipment owner remains responsible for shaft design, stress and fatigue analysis, bearing system, drive train, operating envelope, overspeed protection and approval of material substitutions. Final grade, forging route, heat treatment, dimensions, fillets, surface condition and installation must follow the approved drawing and purchase specification.
1. Product boundary and supply condition
A crankshaft forging is not automatically a finished crankshaft. The commercial scope must state where manufacturing responsibility starts and ends. Large offsets, webs, journals and oil passages require coordinated forging, heat treatment, machining and inspection planning.
| Supply condition | Included definition | Buyer interface |
|---|---|---|
| Heat-treated forged blank | Forging envelope, test material and scale condition | Buyer controls all finish machining |
| Rough-machined forging | Cleanup dimensions, stock and UT condition | Buyer confirms remaining stock and datums |
| Semi-finished crankshaft | Defined journals/webs with later finishing | Responsibility split is marked on drawing |
| Finished crankshaft | All dimensions, passages, finish and final inspection | Complete OEM-controlled specification required |
| Replacement based on survey | Approved dimensional model and service history | Owner validates design and interchangeability |
Do not copy a fatigued or plastically deformed shaft without a design authority. Worn journals, blended cracks and prior repairs can conceal original geometry. An RFQ based on a sample needs a controlled measurement plan and written approval of the reconstructed dimensions.
2. 4330V chemistry: use a purchaser-approved specification
“AISI 4330V” is used commercially for Ni-Cr-Mo-V steel, but procurement must not rely on a short grade label. The Liberty Speciality Steels AISI 4330V data sheet publishes the following chemical range for its hot-rolled bar product. It is a supplier-specific reference, not a universal guarantee for all 4330V forgings and not EB’s promised ladle analysis. The customer must provide or approve the governing forging/material specification.
| Element | Liberty data-sheet range, mass % | Engineering relevance for the RFQ |
|---|---|---|
| Carbon, C | 0.28–0.33 | Controlled for strength/hardening response and weld-repair restrictions |
| Silicon, Si | 0.20–0.30 | Controlled deoxidizing/alloy constituent |
| Manganese, Mn | 0.75–1.00 | Contributes to hardenability and steelmaking control |
| Phosphorus, P | 0.015 maximum | Restricted residual |
| Sulfur, S | 0.0015 maximum | Restricted residual in this supplier data sheet |
| Chromium, Cr | 0.75–1.00 | Part of Ni-Cr-Mo alloy design |
| Molybdenum, Mo | 0.35–0.50 | Part of hardenability/tempering response |
| Nickel, Ni | 1.65–2.00 | Major alloying addition in the referenced product |
| Aluminum, Al | 0.015–0.035 | Controlled range in the referenced steelmaking practice |
| Vanadium, V | 0.05–0.10 | Microalloying addition requiring heat analysis control |
The same data sheet describes specific bar diameters, steelmaking and heat-treatment options. Those statements must not be presented as EB’s forging route. A crankshaft purchase should state heat analysis, permitted residuals, cleanliness requirements, ingot/billet route, reduction expectations and any customer specification that supersedes the data-sheet ranges.
3. Metal elements do not replace a heat-treatment specification
Nickel, chromium, molybdenum and vanadium influence hardenability, tempering behavior and microstructure, but chemical conformance does not prove through-section properties in a large forging. Section size, prior austenite condition, quench severity, furnace uniformity and tempering determine the delivered condition.
| Control | Evidence provided | Limitation |
|---|---|---|
| Ladle chemistry | Heat composition against agreed limits | Does not show local microstructure or defects |
| Heat-treatment chart | Time/temperature record for the load | Does not independently prove mechanical properties |
| Tensile/impact tests | Coupon properties at specified location/orientation | May not represent every shaft location |
| Hardness survey | Local surface hardness distribution | Does not prove toughness or fatigue life |
| Metallography, if ordered | Sampled microstructure and decarburization | Sampling is local and destructive |
The drawing or purchase specification must define the required strength condition, test locations, orientation, specimen removal stage and retest rules. Do not ask a supplier simply to “heat treat to 4330V.”
4. Forging-route review for webs, throws and journal stock
The manufacturing plan should establish starting stock, forging sequence, fiber-flow objectives, reduction, test prolongations and removal of segregated or unsound zones. Complex crank geometry may require staged forging and substantial machining. The final route depends on mass, throw, press capacity, tooling and approved acceptance criteria.
| Forging input | Question for technical review | Required record when contracted |
|---|---|---|
| Starting material | Ingot, bloom or billet; melt/refining route | Heat and material traceability |
| Reduction | How is deformation distributed through the section? | Process record or agreed calculation |
| Test prolongation | Where are mechanical-test coupons located? | Marked forging drawing |
| Grain flow | What orientation is required around journals/webs? | Macroetch or process evidence if specified |
| Machining envelope | Where is stock needed for cleanup and UT? | Stage drawing with dimensions |
EB Castworld confirms feasible route only after reviewing the controlled model and required capacity. This page does not claim that every listed size, offset or weight can be produced.

5. Heat treatment and mechanical-property definition
Specify whether the forging is normalized, quenched and tempered, stress relieved or delivered in another approved condition. Define furnace qualification requirements, thermocouple placement, transfer limits and chart retention if these are contractual. The Liberty data sheet references several minimum yield-strength variants for its bar product; those variants cannot be transferred automatically to a different crankshaft forging.
| Property | RFQ definition | Common ambiguity to remove |
|---|---|---|
| Tensile strength | Required range and test standard | Minimum only versus controlled range |
| Yield strength | Offset method and requirement | 0.2% offset versus other definitions |
| Elongation/reduction of area | Gauge and minimum | Orientation and specimen size |
| Impact toughness | Temperature, specimen, orientation and minimum/average | Room-temperature result used for cold service |
| Hardness | Scale, locations and range | Conversion substituted for actual test |
If hardness conversion is permitted, state the accepted standard and limits. If through-thickness uniformity is important, specify a technically achievable sampling or qualification plan rather than inferring uniformity from accessible surface readings.
6. Ultrasonic testing must be ordered with coverage and acceptance
The ASTM A388/A388M product page describes ultrasonic examination of steel forgings using agreed procedures. A purchase order should identify the standard edition, scan surfaces, examination stage, coverage, frequency, calibration reflectors, recording level and acceptance criteria. Saying “UT according to ASTM A388” is incomplete because the purchaser and supplier must agree key details.
| UT requirement | What to put in the RFQ | Why it matters |
|---|---|---|
| Examination stage | Heat-treated blank, rough machined or final | Surface condition and geometry affect testability |
| Scan coverage | Journals, webs, throws and excluded zones | Prevents assumptions about inaccessible areas |
| Calibration | Block type, diameter/FBH or other basis | Establishes reproducible sensitivity |
| Recording/acceptance | Amplitude, length, number and location rules | Separates reportable from rejectable indications |
| Report | Equipment, probe, operator, map and results | Supports traceable review |
Large grain, curved surfaces and complex geometry can limit ultrasonic response. The supplier should perform a testability review before accepting coverage. UT reduces uncertainty about specified discontinuities; it does not certify infinite fatigue life.
7. Surface examination and magnetic-particle testing
For ferromagnetic steel, magnetic-particle examination may detect surface and slightly subsurface discontinuities. ASTM’s current product information for E1444/E1444M explains the method and notes that a detailed written procedure and engineering requirements are needed. For general industrial forgings, the purchaser may instead specify another applicable ASTM practice or an OEM procedure; do not cite an aerospace practice automatically.
| MT/PT input | Required definition | Practical note |
|---|---|---|
| Method | Wet fluorescent, visible or other approved method | Match governing specification |
| Surface condition | As-forged, machined, ground or final | Rough surfaces can reduce sensitivity |
| Coverage | Fillets, journals, oil-hole edges and other zones | Mark zones on drawing |
| Magnetization | Direction and technique | Discontinuity orientation affects detection |
| Acceptance | Indication type, length, spacing and disposition | “No cracks” needs a formal method and criteria |
Any grinding or blend repair needs prior limits and post-repair examination. Weld repair of a highly stressed crankshaft must not be assumed acceptable. It requires design approval, a qualified procedure, heat-treatment assessment and documented reinspection—or may be prohibited entirely.
8. Dimensional design inputs and fatigue-sensitive features
Journal diameter, throw, web thickness, fillet radii, oil holes, keyways and flange transitions can be fatigue-sensitive. These must come from the approved design. Do not alter a fillet to simplify machining or polishing without written approval. Define surface finish measurement direction and any residual-stress process such as fillet rolling or shot peening only if it is a qualified drawing requirement.
| Characteristic | Drawing control | Inspection evidence |
|---|---|---|
| Main/rod journals | Size, cylindricity and finish | Dimensional and roughness report |
| Throw relationship | Position, stroke and phase angle | Coordinate or dedicated measurement report |
| Fillet | Radius/profile and transition | Profile check and surface examination |
| Oil holes | Diameter, path, edge treatment and cleanliness | Borescope/flow/cleanliness record if ordered |
| Flange/keyway | Datum position, runout and geometry | Ballooned inspection report |
| Balance | Condition, speed and grade | Balance report if contractually required |
Measurement temperature and support condition matter on long shafts. State whether inspection occurs between centers, on defined journals or with another fixture. The customer should supply any proprietary gauge or master requirement before quotation.
9. Machining sequence and stock control
Rough machining can expose subsurface material and create surfaces suitable for UT. Finish machining establishes journals and datums but reduces the remaining repair allowance. Coordinate UT, mechanical tests, stress relief and final finishing so a late operation does not invalidate earlier results.
| Stage | Hold point | Release evidence |
|---|---|---|
| Forging complete | Visual/traceability review | Traveler and forging record |
| Heat treatment complete | Chart and test review | Heat-treatment report |
| Rough machining | Cleanup and stock confirmation | Dimensional stock map |
| NDT | Review indications before finishing | Signed NDT report and map |
| Final machining | Critical dimensions and surfaces | Ballooned report |
| Packing | Cleanliness, preservation and supports | Release checklist/photos |
If the customer will finish-machine, EB needs the buyer’s minimum stock and acceptance dimensions. If EB performs finishing, the full design definition, tool access, critical characteristics and final inspection format are required.
10. Quality dossier and traceability
The required manufacturing record book should be listed in the RFQ. Avoid requesting “full documentation” without identifying contents, review points and language. A practical dossier may include material certificates, melt route, forging record, heat-treatment charts, mechanical tests, NDT procedures and reports, dimensional inspection, nonconformance dispositions and final marking.
| Dossier item | Minimum linkage | Buyer decision |
|---|---|---|
| Material certificate | Heat number and specification | Certificate type and witnessing |
| Process traveler | Forging ID through each operation | Retention period |
| Heat-treatment chart | Furnace/load and shaft identity | Review/approval hold point |
| Test reports | Specimen location and heat/part ID | Raw data versus summary |
| Dimensional report | Drawing revision and balloon numbers | Critical or full inspection |
| Deviation record | Requirement, disposition and approver | Approval authority |
Marking must survive intermediate operations or be transferred under control. State final marking location, method, character size and any prohibition on stamping highly stressed surfaces.
11. Service data needed to quote responsibly
Even when EB manufactures strictly to drawing, operating context helps identify missing requirements. Provide pump type, stroke, speed, normal and peak load, pressure cycles, driver behavior, environment, lubrication system, bearing arrangement and failure history. For a failed shaft, include fracture-protection measures and laboratory evidence where available.
| Service information | Purchasing use | Boundary |
|---|---|---|
| Speed and cycle | Review dynamic and inspection requirements | Buyer/OEM performs stress rating |
| Load/pressure history | Distinguish normal, peak and upset duty | Not converted into a warranty by supplier |
| Temperature/environment | Review material and preservation needs | Site controls remain owner responsibility |
| Lubrication/cleanliness | Identify oil-passage and packing needs | Supplier does not redesign system automatically |
| Failure evidence | Prevent blind copying of a failed condition | Root-cause approval belongs to competent engineer |
12. Installation and safety boundary
A heavy crankshaft can move unexpectedly and contains pinch, lifting and stored-energy hazards. Follow engineered lifting plans, equipment manufacturer instructions and the site’s isolation procedure. The OSHA hazardous-energy-control page gives general lockout/tagout context; local law and employer rules govern actual servicing.
This page is not a lifting plan, alignment procedure or commissioning instruction. Verify lifting points and center of gravity, protect finished journals, confirm bearing clearances and lubrication, check drive alignment and complete OEM acceptance before operation.
13. AISI 4330V forged crankshaft RFQ checklist
Minimum package for a technically useful review
- controlled 2D drawing and 3D model with revision;
- finished and forging-envelope dimensions, mass and required stock;
- material specification, edition, 4330V chemistry and permitted melt route;
- required forging process, reduction evidence and test prolongations;
- heat-treatment condition, furnace controls and mechanical properties;
- tensile, impact, hardness and metallography sampling plan;
- UT standard, edition, stage, coverage, calibration and acceptance;
- surface NDT method, zones, stage and acceptance criteria;
- journal/fillet/oil-hole finish and dimensional characteristics;
- balancing, cleanliness, preservation, lifting and packing requirements;
- manufacturing record book index and third-party hold points;
- quantity, forecast and written deviation-approval route.
14. Related resources and quotation route
For a detailed explanation of forged-shaft examination planning, read the forged shaft ultrasonic testing guide. For fit and fretting inputs at connected drive components, see the coupling hub bore-fit and keyway guide. These resources support RFQ preparation; they do not replace the crankshaft designer’s calculations.
Send the controlled package through Contact EB Castworld, email sales@ebcastworld.com, and review the factory capability page. We will confirm manufacturing feasibility, process boundaries, inspection documentation and quotation assumptions before accepting an order. Final material, dimensions and acceptance remain governed by the customer-approved drawing and purchase specification.

Image sources and reuse permissions
- Featured image: Image title: Klika – postup.jpg. External engine-crankshaft process display; not an EB product, mud-pump design or capability record. External reference photograph/micrograph; not an EB Castworld project or test record. Author: Jindřich Běťák. Source on Wikimedia Commons. CC BY-SA 3.0. Downloaded as a Wikimedia Commons display-size derivative; no other pixel editing. WordPress may create additional display sizes; license retained.
- Figure 1: Image title: VK Huette Schmiedeprodukt.JPG. External die-forged crankshaft with flash; not an EB product, 4330V sample or proof of EB equipment capacity. External reference photograph/micrograph; not an EB Castworld project or test record. Author: TeWeBs. Source on Wikimedia Commons. CC BY-SA 4.0. Downloaded as a Wikimedia Commons display-size derivative; no other pixel editing. WordPress may create additional display sizes; license retained.
- Figure 2: Image title: Example of a Cylindrical Coordinate Measuring Machine.jpg. External branded crankshaft gauge; not EB equipment and no brand relationship or measurement capability is implied. External reference photograph/micrograph; not an EB Castworld project or test record. Author: Turbonut. Source on Wikimedia Commons. CC BY-SA 4.0. Downloaded as a Wikimedia Commons display-size derivative; no other pixel editing. WordPress may create additional display sizes; license retained.